What was found
STRINGER 24P, BETWEEN FRAMES X373.1 TO X428.5, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION. CLEANED REMOVED RIVETS AND REMOVED CORROSION IAW SRM 51-26-10-02-01, 51-42-05-02-01 AND SRM 51-21-00-00-02. CONFIRMED AREA IS CRACK FREE REF NTM 51-00-04-910-801 PT 1. REMAINING THICKNESS .076. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-4671. APPLIED ALODINE, PRIMER AND PAINT IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01. APPLIED EXTERIOR PRIMER AND PAINT IAW SRM 51-25-10-02-01, 51-25-05-02-01.