What was found
STRINGER 33, BETWEEN FRAMES X-39 TO X49.5, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED, MAY INCLUDE FWD ATTACH FITTING AND SKIN ADJACENT TO STRINGER. REMOVED 10 FASTENERS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. REMOVED BUBBLING PAINT IAW SRM 51-26-00-02-03. MIN REMAINING THICKNESS NOTED .040" REF NTM 51-00-04-910-801 PT 1. CONFIRMED CRACK FREE CONDITION OF AFFECTED AREA REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-4685.