As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CENTER LINE FLOORBOARD ATTACH TEE AND ASSOCIATED STRUCTURE AND HARDWARE AT FRAME X1.0 IS CORRODED. REMOVED CENTER LINE FLOORBOARD ATTACH T FOR REPLACEMENT IAW SRM 51-42-15-02-01. ATTACH T FOUND TO BE OUT OF LIMITS IAW SRM 53-20-43-00-01. CORROSION LIMITED TO T. MATCH DRILLED NEW PART IAW SRM 51-40-07-02-01. PREPPED, TREATED AND PRIMED NEW T IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED FLOORBOARD ATTACH T IAW SRM 51-42-05-02-01. PRIMED RIVETS IAW SRM 51-25-10-02-01.