What was found
FRAME X32.4, FLANGES, BETWEEN STRS 30S - 33 BUBBLING PAINT/PROBABLE CORROSION. REMOVED 17 RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .029 REF NTM 51-00-04-910-801 PT 1 AND RD 8/4-53-4708. VERIFIED FRAME FLANGES ARE CRACK FREE REF NDTM PART 1, TASK 51-00-06-910-801. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-4708. INSTALLED 17 RIVETS IAW SRM 51-42-05-02-01. APPLIED ALUMINIZED PAINT AND CPC IAW RD 8/4-53-4708. APPLIED EXTERIOR PAINT IAW RD 8/4-53-4708. COMPLIED WITH TASK CARD RD 8/4-53-4708.