What was found
FRAME X258, FLANGES BETWEEN STRS 25S-26S AND 28S-32S BUBBLING PAINT/PROBABLE CORROSION. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED 4 RIVETS, PAINT PRIMER AND CORROSION IAW SRM 51-42-05-02-01, AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .039" CONFIRMED CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW RD 8/4-53-2344. PREPPED, PRIMED AND TOP COATED FLANGES IAW SRM 51-21-10-02-01 AND 51-25-10-02-01.