What was found
FRAME X1.0 FLANGES BETWEEN STRS 30S-33 BUBBLING PAINT/PROBABLE CORROSION. REMOVED FOUR RIVETS AND BLENDED CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS NOTED .045" REF NTM 51-00-04-910-801 PT 1. VERIFIED BLENDED AREAS TO BE CRACK FREE IAW NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND WITHIN LIMITS IAW RD 8/4-53-4694 AND RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED ALODINE, PRIMER AND TOPCOAT IAW RD 8/4-53-4694. COMPLIED WITH TASK CARD RD 8/4-53-4694.