What was found
CLEANED FRAME AND FLANGES IAW SRM 51-26-00-02-01. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. CORROSION FOUND OUT OF LIMITS IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .029", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. REINFORCING ANGLE FOUND IN LIMITS IAW RD 8/4-53-4721. ALODINED AND PRIMED REINFORCING ANGLE IAW RD 8/4-53-4721. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED PRIMER, TOPCOAT AND CPC IAW RD 8/4-53-4721. COMPLIED WITH TASK CARD RD 8/4-53-4721.