What was found
STRINGER 31S BETWEEN FRAMES X49.5 TO 236, MULTIPLE AREAS OF BUBBLING PAINT, PROBABLY CORROSION AND/OR SURFACE PROTECTION NEEDED, MAY INCLUDE FWD ATTACH ITEMS. CLEANED AREA IAW SRM 51-26-00-02-01, REMOVED CORROSION IAW SRM 51-21-00-02-01. STRINGER SPLICE FOUND OUT OF LIMITS IAW SRM 51-14-00-02-03. LOCATED NEW STR SPLICE AND MATCH DRILL STR 31.5 AND X102 TO X112 IAW SRM 51-40-07-02-01. INSTALLED NEW STR SPLICE IAW SRM 51-42-05-02-01 AND 51-40-15-02-01. PRIMED AND APPLIED TOPCOAT IAW SRM 51-25-10-02-01 AND SRM 51-25-25-02-01.