As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLAP POWER CAUTION WHEN SELECTING FLAPS TO 35 DEGREES. FLAPS STAYED AT 15 DEGREES. FOLLOWED EAC CHECKLIST, FLAP POWER CAUTION RETURNED. LANDING UNEVENTFUL. PERFORMED FIM TASK 27-50-00-810-802. FAULT NOTED AS CURRENT - ECU CONTINUOUS BIT. PERFORMED FIM TASK 27-50-00-810-807. FAULT CLEARED. FLAPS CHECKED GOOD. RAN FLAPS 10 DEGREES-15 DEGEES-35 DEGREES SEVERAL TIMES FOR GOOD MEASURE. OK FOR SERVICE.