What was found
STRINGER 32P BETWEEN FRAMES X-39 TO X49.5, MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED. RMOVED RIVETS AS NECESSARY IAW SRM 51-42-05-02-01 AND CLEANED IAW SRM 51-21-00-00-02 AND 51-26-00-02-01. CORROSION LIMITED TO Z-JOINT. MATCH DRILLED NEW PART IAW SRM 51-40-07-02-01. INSTALLED NEW Z-JOINT IAW SRM 51-42-05-02-0`1. APPLIED ALODINE, PRIMER, TOPCOAT AND CPC IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801.