What was found
FRAME BS 341 FLANGES, BETWEEN STRS 31P-33 BUBBLING PAINT/PROBABLE CORROSION. CLEANED FRAME FLANGES IAW SRM 51-26-00-02-01. REMOVED PAINT IAW SRM 51-26-10-02-01. CLEANED, REMOVED RIVETS AND CORROSION IAW 51-21-00-00-02, AND 51-42-05-02-01. MIN REMAINING THICKNESS NOTED .045", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS WITHIN LIMITS IAW RD 8/4-53-4707 AND RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED ALUMINIZED TOPCOAT AND CPC IAW RD 8/4-53-4707. COMPLIED WITH TASK CARD RD 8/4-53-4707.