What was found
STRINGER 31S, BETWEEN FRAMES X-39 TO X49.5 MULTIPLE AREAS OF BUBBLING PAINT, PROBABLE CORROSION AND/OR SURFACE PROTECTION NEEDED MAY INCLUDE FWD ATTACH FITTING. CLEAN IAW SRM 51-26-10-02-01. REMOVED 10 RIVETS IAW SRM 51-42-05-02-01, AND REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .056", CONFIRMED CRACK FREE AREA REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-4677. ALODINE AND PRIMED WORKED AREA IAW SRM 51-25-10-02-01 AND 51-21-10-02-01. INSTALLED RIVETS, APPLIED ALODINE, PRIMER AND ALUMINIZED PAINT IAW SRM 51-42-05-02-01, SRM 51-25-15-02-01. COMPLIED WITH TASK CARD RD 8/4-53-4677.