What was found
FRAME X136, FLANGES BETWEEN STRS 26P-33 BUBBLING PAINT PROBABLE CORROSION. REMOVED FASTENERS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .037" REF NTM 51-00-04-910-801 PT 1. MATERIAL LOSS FOUND OUT OF LIMITS IAW SRM 53-20-15-00-01. REMOVED FRAME IAW RD 8/4-53-4690. ENSURED REMAINING SECTION OF FRAME CRACK FREE REF NDTM 51-00-06-910-801 PT 1. FABRICATED SPLICE IAW RD 8/4-53-4690. MATCH DRILLED NEW FRAME AND APPLIED PROTECTIVE COATING IAW RD 8/4-53-4690. VERIFIED CUT EDGE OF REPLACEMENT SECTION ARE CRACK FREE IAW SRM 51-00-06-910-801 PT 1. INSTALLED NEW FRAME IAW RD 8/4-53-4690. APPLIED INTERIOR, EXTERIOR SURFACE PROTECTION AND CPC IAW RD 8/4-53-4690. COMPLIED WITH TASK RD 8/4-53-4690.