What was found
FRAME 1.0 FLANGE HAS CORROSION BETWEEN STR 32-31S. REMOVED RIVETS AS REQUIRED IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. POLISHED SURFACE REF RD 8/4-53-2344. MIN REMAINING THICKNESS .046, CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. ALODINED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-25-10-02-01, 51-25-15-02-01 AND APPLIED CPC IAW AMM 51-25-01-390-801.