What was found
FRAME X94.8 FLANGES, BETWEEN STRS 26S-29S AND 30S-33, BUBBLING PAINT/PROBABLE CORROSION. REMOVED RIVET AS NECESSARY, REMOVED CORROSION AND LOOSE PAINT IAW SRM 51-42-05-02-01, 51-21-00-00-02 AND 51-26-00-02-03. MIN REMAINING THICKNESS NOTED .037 REF NTM 51-00-04-910-801 PT 1. VERIFIED AREA IS CRACK FREE REF NDTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-4701 AND RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS AND APPLIED ALUMINIZED PAINT IAW RD 8/4-53-2344. COMPLIED WITH TASK CARD RD 8/4-53-4701.