What was found
FRAME X156 FLANGES BETWEEN STRS 26P-33 BUBBLING PAINT/PROBABLE CORROSION. REMOVED RIVETS AS REQUIRED IAW SRM 51-42-05-02-01, REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. MIN REMAINING THICKNESS .037 REF NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS AND MATERIAL LOSS FOUND WITH IN LIMITS IAW RD 8/4-53-4700 AND RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-2344. APPLIED TOP COAT AND CPC IAW RD 8/4-53-2344. COMPLIED WITH TASK CARD RD 8/4-53-4700.