What was found
FRAME X32.4 FLOOR SUPPORT CHANNEL AND PLATE ABOVE STRINGERS 14P-28P MANY CORRODED FASTENERS. REMOVED DRAFT BULKHEAD ANGLE DUE TO NO CORROSION ALLOWED IAW SRM 51-42-45-02-01 AND 51-42-05-02-01. RECEIVED NEW T FITTING AND ANGLE. MATCH DRILL TO ACFT IAW SRM 51-40-07-02-01. RECEIVED NEW DRAFT BULKHEAD ANGLE MATCH DRILLED TO ACFT IAW SRM 51-40-07-02-01. INSTALLED T FITTING AND FWD DRAFT BULKHEAD ANGLE IAW SRM 51-42-05-02-01.