What was found
FRAME X136, FLANGES BETWEEN STRS 29S-33 BUBBLING PAINT/PROBABLE CORROSION. REMOVED RIVETS AS NECESSARY AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS .036" REF NTM 51-00-04-910-801 PT 1. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. BLENDS FOUND IN LIMITS IAW RD 8/4-53-4693 AND RD 8/4-53-2344. PREPPED, INSTALLED RIVETS AND RESTORED SURFACE PROTECTIONS IAW RD 8/4-53-4693, SRM 51-25-10-02-01, 51-25-15-02-01, AND AMM 51-25-01-390-801. COMPLIED WITH RD 8/4-53-4693.