What was found
FRAME X71.2 FLANGES BETWEEN STRS 29S-33 BUBBLING PAINT/ PROBABLE CORROSION. REMOVED RIVETS AS NECESSARY AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .026" REF NTM 51-00-04-910-801 PT 1. VERIFIED FRAME FLANGES CRACK FREE REF NTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-4711 AND RD 8/4-53-2344. CUT OFF SKIN FLANGE AT FRAME 71.2 BETWEEN STRS 31-30S IAW RD 8/4-53-4711 AND 53-10-15-02-01. ALODINED AND PRIMED IAW SRM 51-21-10-02-01, AND 51-25-10-02-01. INSTALLED RIVETS IAW SRM 51-42-05-02-01.