What was found
FRAME X49.5 FLANGES BETWEEN STRS 32P-33 BUBBLING PAINT/PROBABLE CORROSION. REMOVED RIVETS AS NEEDED IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .040 REF NTM 51-00-04-910-801 PT 1. CERIFIED AREA CRACK FREE REF NDTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND OUT OF LIMITS IAW RD 8/4-53-2344. REMOVED FRAME FLANGE AND FABRICATED NEW FLANGE IAW RD 8/4-53-017. CONFIRMED FRAME WEB CRACK FREE AT CUT LINE REF 51-00-06-910-801 PT1. INSTALLED REPAIR IAW RD 8/4-53-017. APPLIED SURFACE PROTECTION AND CPC REF RD 8/4-53-017.