As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INTERCOSTAL ON STRINGER 27S BETWEEN FRAMES 683-664 IS CORRODED. REMOVED CORROSION IAW SRM 51-21-00-00-02 AND REMOVED RIVETS IAW SRM 51-42-05-02-01. MIN REMAINING THICKNESS .023, CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-4704. ALODINED AND PRIMED IAW RD 8/4-53-4704. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED TOPCOAT AND CPC IAW RD 8/4-53-4704. COMPLIED WITH TASK CARD RD 8/4-53-4704.