What was found
FRAME X1.0 FLANGES BETWEEN STRS 31P-33 BUBBLING PAINT PROBABLE CORROSION. REMOVED FRAME IAW SRM 51-42-05-02-01. MATCH DRILLED NEW FRAME SECTION TO AC IAW SRM 51-40-07-02-01. INSTALLED FRAME, FRAME SPLICE IAW SRM 51-42-05-02-01. CONFIRMED REPAIR AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. APPLIED PRIMER, ALUMINIZED PAINT AND CPC IAW SRM 51-25-10-02-01 AND AMM 51-25-01-390-801 AND 51-25-15-02-01. COMPLIED WITH TASK CARD RD 8/4-53-2344.