What was found
STRINGER 30P BETWEEN FRAMES X-39 TO X 49.5 MULTIPLE AREAS OF BUBBLING PAINT PROBABLE CORROSION AND OR SURFACE PROTECTION NEEDED. CLEANED IAW SRM 51-26-00-02-03. CORROSION FOUND LIMITED TO Z-JOINT AND IS OUT OF LIMITS IAW SRM 53-10-33-01-01. MATCH DRILLED NEW Z-JOINT IAW SRM 51-42-05-02-01 AND 51-40-07-02-01. INSTALLED Z-JOINT IAW SRM 51-42-05-02-01. APPLIED ALUMINIZED PAINT AND CPC IAW SRM 51-25-15-02-01 AND AMM 51-25-01-390-801.