As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT NR 4 FLAP TRACK BEAM INBD WEB COATING AT FWD END WORN. BLENDED IAW RD 8/4-57-1238. MIN REMAINING THICKNESS .155" REF NTM 51-00-04-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-57-1238. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 8.2.1.