What was found
FRAME 94.8 HAS CORROSION BETWEEN STR 32-29S. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS FOM IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .036', CONFIRMED CRACK FREE AREA REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. FOUND WITHIN LIMITS IAW DWG 85329294 AND RD 8/4-53-2344. ALODINED AND PRIMED FRAME IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED RIVETS IAW SRM 51-42-05-02-01. RESTORED SURFACE PROTECTION IAW SRM 51-25-10-02-01, AND 51-25-05-02-01.