What was found
FRAME 19.4 HAS CORROSION BETWEEN STR 32-30S. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .030" CONFIRMED AREA CRACK FREE REF 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND OUT OF LIMITS IAW RD 8/4-53-2344. CUT OUT DAMAGED FLANGE IAW RD 8/4-53-017. CONFIRMED CUT OUT IS CRACK FREE USING HFEC REF NDTM 51-00-06-910-801, PT 1. FABRICATED ANGLE REPAIR, ALODINED, PRIMED AND APPLIED ALUMINIZED PAINT IAW RD 8/4-53-017. INSTALLED RIVETS IAW RD 8/4-53-2344. TOP COATED EXTERIOR SKIN IAW SRM 51-25-05-02-01.