What was found
INTERIOR FUSELAGE SKIN HAS CORROSION BETWEEN FR -39-18.25 STR 30-28S. REMOVED CORROSION AND CORRODED RIVETS, CORROSION WAS LIMITED TO SKIN STRAP AT -18.25. WORK PERFORMED IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .030", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. BLENDS ARE WITHIN LIMITS IAW RD 8/4-53-4752. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED SURFACE PROTECTION INSIDE AND OUT IAW RD 8/4-53-4752. COMPLIED WITH TASK CARD RD 8/4-53-4752.