What was found
EMERGENCY EXIT DOOR, AFT THRESHOLD TO FRAME ATTACH FITTING CORRODED. REMOVED FRAME ATTACH FITTING IAW SRM 51-42-05-02-01. RECEIVED FITTING, MATCH DRILLED TO AC AND INSTALLED IAW SRM 51-40-07-02-01 AND 51-40-15-02-01. APPLIED PRIMER AND TOPCOAT IAW SRM 51-25-10-02-01 AND 51-25-15-02-01.