What was found
INTERIOR FUSELAGE SKIN LAP JOINT HAS CORROSION BETWEEN FR 116-136 AT STR 31P. CLEANED AREA IAW SRM 51-26-00-02-01. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. BLENDED OUT CORROSION IAW SRM 51-21-00-00-02 MIN REMAINING THICKNESS .042" CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. BLENDS ARE WITHIN LIMITS IAW RD 8/4-53-4758. TRIMMED OUT EXTERNAL JOINT STRAP AND FABRICATED REPAIR STRAP IAW RD 8/4-53-731 AND RD 8/4-53-4758. ENSURED REPAIR AREA WAS CRACK FREE USING HFEC REF NDTM 51-00-01-250-801, PT 6. INSTALLED SPLICE REPAIR STRAP AND RIVETS IAW RD 8/4-53-731 AND SRM 51-42-05-02-01. ALODINED, PRIMED, ALUMINIZED AND APPLIED CPC TO AREA IAW RD 8/4-53-4758. PRIMED EXTERIOR IAW SRM 51-25-15-02-01. SEALED AND PAINTED EXTERIOIR SURFACE IAW RD 8/4-53-4758. COMPLIED WITH TASK CARD RD 8/4-53-4758.