As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BOTH INBD OTBD FWD WARDROBE LOWER MOUNT RAILS HAVE CORROSION. REMOVED CORROSION REF SRM 51-21-00-00-02. PERFORMED HFEC OF BLENDS FOR CRACKS IAW NTM 51-00-06-910-801 PT 1, NO CRACKS NOTED. PERFORM UT THICKNESS CHECK IAW NTM 51-00-04-910-801 PT 1. BLENDS FOUND IN LIMITS IAW RD 8/4-53-4749. APPLIED ALODINE, PRIMER, ALUMINIZED PAINT AND CPC IAW RD 8/4-53-4749. COMPLIED WITH TASK CARD RD 8/4-53-4749.