What was found
FUSELAGE SKIN HAS FRETTING DAMAGE AROUND PERIMETER OF RT ICE SHIELD. REMOVED 7 RIVETS FROM AFT PERIMETER OF RT ICE SHIELD IAW SRM 51-42-05-02-01. REMOVED FRETTING DAMAGE ON SKIN IAW SRM 51-14-00-02-03. MIN REMAINING THICKNESS .035" REF NDTM 51-00-02-250-801 PT 4, CONFIRMED PERIMETER OF ICESHIELD CRACK FREE REF NDTM 51-00-01-250-801 PT 6. MATERIAL LOSS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-4796. APPLIED ALODINE PRIMER AND PAINT IAW RD 8/4-53-4796. INSTALLED NEW RIVETS AS REQUIRED IAW SRM 51-42-05-02-01 AND 51-23-00-00-01. COMPLIED WITH TASK CARD RD 8/4-53-4796.