What was found
FRAME BS 281 AT STRINGER 31P IS CORRODED. REMOVED CORROSION ON FWD AND AFT SIDE OF FRAME IAW SRM 51-41-05-00-01, 51-42-05-02-01 AND 51-21-00-00-02. VERIFIED BLENDS CRACK FREE IAW NTM 51-00-06-910-801 PT 1. MEASURED REMAINING THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-4805 AND RD 8/4-53-2344. REINSTALLED ALL FASTENERS IAW SRM 51-42-05-02-01 AND 51-41-05-00-01. APPLIED PAINT REF SRM 51-25-10-02-01. COMPLIED WITH TASK CARD RD 8/4-53-4805.