As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PAX DOOR MAIN HINGE HAS WEAR ON LOWER SURFACE AND BOTH ATTACH POINTS TO FUSELAGE. BLENDED OUT DAMAGE IAW SRM 51-14-00-02-04. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. BLEND IS WITHIN LIMITS IAW RD 8/4-52-824. APPLIED ALODINE PRIMER AND PAINT IAW RD 8/4-52-824. COMPLIED WITH TASK CARD RD 8/4-52-824.