What was found
AFT CARGO FLOOR WEB HAS CORROSION BETWEEN FR 701-714 STR 31-24P. REMOVED CORROSION REF SRM 51-21-00-00-02. PERFORMED HFEC OF BLENDS FOR CRACKS IAW NTM 51-00-06-910-801 PT 1, NO CRACKS NOTED. PERFORMED THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS .037". FOUND TO BE IN LIMITS IAW RD 8/4-53-4742. PRIMED IAW SRM 51-25-10-02-01. APPLIED SURFACE PROTECTION IAW RD 8/4-53-4742. COMPLIED WITH TASK CARD RD 8/4-53-4742.