What was found
FRAME 94.8 FLANGES ARE CORRODED STR 31P-29P. REMOVED REQUIRED RIVETS TO ACCESS CORROSION AND REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS .038". INSPECTED USING HFEC, NO CRACKS NOTED REF NDTM 51-00-06-910-801, PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED ALUMINIZED AND INSTALLED RIVETS IAW RD 8/4-53-2344. PRIMED AND TOP COATED EXTERIOR, APPLIED CPC IAW SRM 51-25-15-02-01 AND RD 8/4-53-2344.