What was found
FRAME 196, FLANGE IS CORRODED STR 30P-29P. REMOVED 2 RIVETS AND CORROSION FROM FRAME IAW RD 8/4-53-2344. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS .038". INSPECTED USING HFEC, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW Q400 RD 8/4-53-2344. APPLIED SURFACE PROTECTION IAW SRM 51-21-10-02-01 AND INSTALLED RIVETS IAW SRM 51-42-05-02-01. PRIMED AND PAINTED EXTERIOR, ALUMINIZED AND APPLIED CPC IAW SRM 51-25-15-02-01 AND RD 8/4-53-2344.