What was found
FRAME 71.2 FLANGE IS CORRODED BETWEEN STRS 28P AND 29P. REMOVED RIVETS FOR CORROSION ACCESS AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS .039". INSPECTED AREA USING HFEC, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. FOUND FRAME TO BE WITHIN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-2344. TOP COATED IAW SRM 51-25-15-02-01. ALUMINIZED AND APPLIED CPC IAW SRM 51-25-10-02-01 AND AMM 51-25-01-390-801.