What was found
FRAME 216, FLANGE IS CORRODED STR 31S-30S. REMOVED RIVETS FROM FLANGE IAW SRM 51-42-05-02-01 AND REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED UT THICKNESS CHECK IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS .038". INSPECTED BLEND WITH HFEC , NO CRACKS NOTED REF NDTM 51-00-06-910-801, PT 1. NOMINAL THICKNESS .040" FOUND FRAME TO BE WITHIN LIMITS IAW RD 8/4-53-2344. APPLIED SURFACE PROTECTION IAW RD 8/4-53-2344. INSTALLED RIVETS AS NECESSARY IAW SRM 51-42-05-02-01. APPLIED EXTERIOR PRIMER AND TOPCOAT IAW SRM 51-25-10-02-01 AND 51-25-05-02-01.