What was found
FRAME 281 FLANGE IS CORRODED STR 31S-30S. REMOVED RIVETS FROM FLANGE IAW SRM 51-42-05-02-01 AND REMOVED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .040" REF 51-00-04-910-801 PT 1. INSPECTED BLEND WITH HFEC , NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. APPLIED SURFACE PROTECTION AND INSTALLED RIVETS AS NECESSARY IAW RD 8/4-53-2344. APPLIED EXTERIOR PRIMER AND TOPCOAT IAW SRM 51-25-10-02-01 AND 51-25-05-02-01.