What was found
FRAME 176, FLANGES ARE CORRODED STR 33-31S. REMOVED RIVETS AS REQUIRED AND REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801, PT 1. MIN REMAINING THICKNESS .037". INSPECTED USING HFEC, NO CRACKS DETECTED REF Q400 NDTM 51-00-06-910-801 PT 1. FRAME FLANGES FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. RESTORED SURFACE PROTECTION IAW RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED PRIMER AND PAINT TO INTERIOR AND EXTERIOR AND COMPLIED WITH RD 8/4-53-2344.