What was found
FRAME 94.8, FLANGES ARE CORRODED STR 32P-32S. REMOVED 12 RIVETS AND CORROSION FROM FRAME IAW RD 8/4-53-2344. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS .039". INSPECTED USING HFEC, NO CRACKS DETECTED REF NDTM 51-00-06-910-801 PT 1. NOMINAL THICKNESS .040", MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-2344. ALODINED, PRIMED AND PAINTED INTERIOR AND EXTERIOR, IAW RD 8/4-53-2344. COMPLIED WITH RD 8/4-53-2344.