What was found
FRAME 156 FLANGES ARE CORRODED STR 30P-28P. REMOVED 5 RIVETS FROM FRAME AND REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN REMAINING THICKNESS .039". INSPECTED BLEND USING HFEC, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. NOMINAL THICKNESS OF .040", FOUND FRAME TO BE WITHIN LIMITS OF RD 8/4-53-2344. APPLIED SURFACE PROTECTION IAW RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED EXTERIOR PRIMER AND PAINT IAW SRM 51-25-10-02-01 AND 51-25-05-02-01. APPLIED INTERIOR ALUMINIZED TOPCOAT IAW RD 8/4-53-2344.