What was found
FRAME 644.5 FLANGE IS CORRODED STR 32P-33P. REMOVED 3 RIVETS FROM FRAME IAW SRM 51-42-05-02-01. BLENDED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS .048" REF NDTM 51-00-04-910-801 PT 1. INSPECTED BLEND USING HFEC, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE WITHIN LIMITS OF RD 8/4-53-2344. ALODINED AND PRIMED WORKED AREAS, INSTALLED RIVETS IAW RD 8/4-53-2344. APPLIED EXTERIOR PRIMER AND PAINT IAW SRM 51-25-10-02-01 AND 51-25-05-02-01. APPLIED INTERIOR ALUMINIZED TOPCOAT IAW RD 8/4-53-2344.