What was found
FOUND CORROSION ON FRAME SPLICE MATING SURFACE AT STA -18.25 AND STR 33. REMOVED SPLICE IAW SRM 51-42-05-02-01. MATCHDRILLED NEW SPLICE IAW SRM 51-40-07-02-01. CORRODED SPLICE FOUND TO BE OUT OF LIMITS IAW SRM 53-20-15-00-01. INSTALLED NEW SPLICE IAW SRM 51-42-05-02-01. APPLIED SURFACE PROTECTION IAW SRM 51-25-10-02-01, 51-25-15-02-01 AND AMM 51-25-01-390-801.