What was found
FRAME 301, FLANGES AND WEB ARE CORRODED STR 30P-27P. REMOVED NECESSARY FASTENERS AND BLENDED OUT CORROSION IAW RD 8/4-53-2344 MIN REMAINING THICKNESS NOTED .037" CONFIRMED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1. REPAIR TO FLANGES IN LIMITS IAW RD 8/4-53-2344 NO BLENDING ALLOWED ON WEB. MATERIAL LOSS ON WEB FOUND TO BE IN LIMITS IAW RD 8/4-53-4824. ALODINED AND PRIMED IAW RD 8/4-53-4824. INSTALLED FASTENERS AS REQUIRED IAW RD 8/4-53-4824. APPLIED PRIMER AND PAINT TO INTERIOR AND EXTERIOR IAW RD 8/4-53-4824. COMPLIED WITH RD 8/4-53-2344 AND RD 8/4-53-4824.