As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STRINGER 33 IS CORRODED AND HAS CORRODED RIVETS AFT OF STA 71.2. REMOVED RIVETS AND CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .053" REF NTM 51-00-04-910-801 PT 1. INSPECTED BLEND USINF HFEC, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. BLENDS FOUND IN LIMITS IAW RD 8/4-53-4867. COMPLETED REPAIRS IAW RD 8/4-53-4867.