What was found
STRINGER 24S IS CORRODED STA 401-413. REMOVED FASTENERS AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS .078", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND WITHIN LIMITS IAW RD 8/4-53-4828. ALODINED, PRIMED, INSTALLED RIVETS, APPLIED TOP COAT AND CPC IAW RD 8/4-53-4828. COMPLIED WITH TASK RD 8/4-53-4828.