As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME 71.2 HAS CORROSION ON THE FLANGE AND WEB STR 33-32P. BLENDED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .036" REF NTM 51-00-04-910-801 PT 1. INSPECTED BLEND WITH HFEC, NO CRACK NOTED REF NDTM 51-00-06-910-801, PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-4863. INSTALLED RIVETS IAW RD 8/4-53-4863. COMPLIED WITH RD 8/4-53-4863.