What was found
FRAME 216, FLANGES ARE CORRODED STR 28P-31P. REMOVED CORROSION IAW RD 8/4-53-2344. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801. MIN REMAINING THICKNESS .037", HFEC INSPECTED BLEND, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. BLENDS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344 AND 8/4-53-4870. INSTALLED RIVETS IAW SRM 51-42-05-02-01. ALODINED, PRIMED AND APPLIED TOP COATS IAW RD 8/4-53-4870.