What was found
FRAME 236, FLANGE IS CORRODED STR 31P-32P. REMOVED FASTENERS AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS .038" REF NTM 51-00-04-910-801 PT 1. FOUND TO BE IN LIMITS RD 8/4-53-2344 AND RD 8/4-53-4876. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-4876. INSPECTED AREA WITH HFEC, NO CRACKS NOTED REF NDTM 51-00-06-910-801 PT 1. APPLIED TOPCOAT AND CPC IAW RD 8/4-53-4876. COMPLIED WITH TASK CARD RD 8/4-53-4876.